Parse Biosciences EvercodeTM WT Mini Kit (10,000 cells/nuclei)
- The maximum number of output barcoded cells/nuclei is 10,000.
- The maximum number of input samples is 12.
- The input number of cells or nuclei (total across all samples) going into Barcoding Round 1 Plate will be 50,000.
Parse Biosciences Evercode WT Kit (100,000 cells/nuclei)
- The maximum number of output barcoded cells/nuclei is 100,000.
- The maximum number of input samples is 48.
- At full kit capacity, the input number of cells or nuclei (total across all samples) going into Barcoding Round 1 Plate will be 350,000.
Parse Biosciences Evercode WT Mega Kit (1M cells/nuclei)
- The maximum number of output barcoded cells or nuclei is 1M.
- The maximum number of input samples is 96 (Evercode WT Mega kit) or 384 (Evercode WT Mega 384 kit).
- At full kit capacity, the total number of cells or nuclei across all samples entering one or four Barcoding Round 1 Plates will be 2.85M for the Evercode WT Mega kit or 3.5M for the Evercode WT Mega 384 kit respectively.
Parse Biosciences Evercode WT Penta Kit (5M cells/nuclei)
- The maximum number of output barcoded cells or nuclei is 5M.
- The maximum number of input samples is 96 (Evercode WT Penta kit) or 384 (Evercode WT Penta 384 kit).
- At full kit capacity, the input number of cells or nuclei across all samples entering one or four Barcoding Round 1 Plates will be 14.4M for the Evercode WT Penta kit or 17.5M for the Evercode WT Penta 384 kit respectively.