The following equipment is required to run a Parse Biosciences EvercodeTM kit.
- Parse Biosciences Magnetic Rack (SB1004)
- Magnetic rack for 1.5 mL tubes.
- Magnetic rack for 15 mL conical tubes1: Permagen® (MSR6X15) or Millipore Sigma® (LSKMAGS15) or Stemcell Technologies® (18103)
- Ring Plate Magnet2: Permagen (s500) or Alpaqua® (A000405)
- Bar Magnet3: Permagen (MSPU650)
- Centrifuge with Swinging Bucket Rotors with adaptors for 1.5 mL tubes4, 15 mL tubes and 96 well plates and capable of reaching 4°C.
- Microcentrifuge compatible with 1.5 mL tubes and 0.2 mL strip tubes.
- Thermal Cycler5 compatible with semi-skirted 96 well plates and 0.2 mL PCR tubes with up to 100 μL of sample volume, sample heating and cooling from 4-98°C, and a heated lid capable of 30-105°C.
- Water bath, thermomixer, heat block, or bead bath capable of holding temperature at 37°C.
- Two heat blocks6: with a range of temperature from 48°C to 68°C and compatible with 1.5 mL, 2 mL, and 5 mL tubes.
- Hemocytometer or other cell counting device7.
- PCR tube rack capable of holding semi-skirted 96 well PCR plates and a tight fitting lid.
- Plate seal applicator capable of adhering plate sealing films to 96 well plates.
- Pipettes: Single channel P20, P200, P1000 and 8 or 12-channel P20, P200.
- Vortex and adapter for 96 well plates that can be set to 800-1000 RPM.
- QubitTM Flex Fluorometer
- 2100 Bioanalyzer or 4200 TapeStation System
- Mr. FrostyTM Freezing Container or styrofoam cooler8
- Freezers: -20°C, -80°C and 4°C.
1 Required for Evercode WT v4 and Evercode MAX WT v4 kits.
2 Only required when running Evercode Low Input Fixation kits on more than 16 samples.
3 Only required for processing more than 16 sublibraries at a time in the Evercode Penta, Evercode Penta 384, or Evercode MAX WT v4 kits.
4 The 1.5mL tube adapter is needed when using Evercode Cell Fixation, 12rxn or Evercode Nuclei Fixation, 12rxn which utilizes 1.5mL tubes.
5 When running Evercode Mega 384, Evercode MAX WT L-384, or Penta 384, two thermal cyclers are required to accommodate 384 sample processing.
6 Only required when running Evercode BCR or Gene Select kits.
7 A cell counter compatible with fluorescent dyes (e.g., AO/PI) is required for Evercode Low Input Fixation, and all Evercode WT v4 workflows (Evercode WT, MAX WT, TCR, BCR). If automation is not available, a fluorescent microscope with compatible hemocytometer slides can be used. For all other workflows, a brightfield based automated cell counter or hemocytometer may be used. Prior to use with a new cell type, we recommend validating the automated cell counter by comparing to a manual count on a hemocytometer.
8 Fixed samples should be slowly cooled for storage at -80°C. A Mr. Frosty Freezing Container should be used when fixed samples are stored in 1.5mL tubes. When fixed samples are stored in 0.2mL PCR strip tubes or PCR plates, a styrofoam cooler can be used for slow cooling instead.